EasyManua.ls Logo

Daewoo Mega 500-V - Table of Fault Codes - ERGO-Control

Daewoo Mega 500-V
686 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S0607900C
Page 32
Transmission Error Codes (ZF)
TABLE OF FAULT CODES - ERGO-CONTROL
Error Code
Number
Meaning of Error Code Remarks
11 Logical error at gear range signal.
12 Logical error at direction select signal.
21 Short circuit to battery voltage at clutch cutoff input.
22 Short circuit to ground or open circuit at clutch cutoff input.
23 Short circuit to battery voltage at load sensor input. Not used.
24 Short circuit to ground or open circuit at load sensor input. Not used.
25 Short circuit to battery voltage or open circuit at temperature sensor
input.
26 Short circuit to ground at temperature sensor input.
31 Short circuit to battery voltage at engine speed input.
32 Short circuit to ground or open circuit at engine speed input.
33 Logical error at engine speed input.
34 Short circuit to battery voltage at turbine speed input.
35 Short circuit to ground or open circuit at turbine speed input.
36 Logical error at turbine speed input.
37 Short circuit to battery voltage at internal speed input.
38 Short circuit to ground or open circuit at internal speed input.
39 Logical error at internal speed input.
AHO0980L
Figure 2

Table of Contents

Related product manuals