EasyManuals Logo

Datalogic AV7000 Reference Manual

Datalogic AV7000
337 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #266 background imageLoading...
Page #266 background image
AV7000 LINEAR CAMERA REFERENCE MANUAL
254
5
NOTE: If pulsed illumination is enabled in Device
Settings | Camera n (unit being calibrated) | Imaging,
Global Gain with Pulsed Illumination should be
adjusted. If pulsed illumination is not enabled, make
adjustments to Global Gain with Continuous
Illumination.
6. Adjust the gain until the white level shown in the Image Viewer is between 180 and 200.
0.
Global
Gain
Value

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals