Figure 129: Controller Key
9. With the unit powered up, hold down buttons 1 and 2 at the same time. The STATUS
LED (located to the right of button #2) will blink GREEN and then RED to indicate that the
unit has been defaulted.
Figure 130: Buttons Close-up
10. Disconnect the power connection from the camera assembly.
11. Remove the CONTROLLER KEY from the I/O port of the AV7000.
12. Re-attach all of the cables to the camera in their original locations.
13. Apply power to the AV7000 Camera.
14. Connect the browser to any AV7000 in the tunnel EXCEPT the unit being replaced.
15. Navigate to the System Info page.
16. In the “This Cluster” section of the page the failed camera will show up with the “Delete”
option in the Action column. Note the MAC address of this camera.
17. The replacement AV7000 will be found in the “Cameras not in the Cluster” portion of the
page.