DVP-15MC Series Motion Controller Operation Manual
11-102
1
2 3
4
5
ReadAtPos_Bsy
ReadAtPos_Err
ReadAtPos_ErrID
ReadAtPos_Pst
ReadAtPos_ValdAxis1
Rel_Ex
MC_ReadActualPosition
Axis Valid
ReadAtPos
Enable Busy
Error
ErrorID
Position
Rel_Bsy
Rel_Act
Rel_Abt
Rel_Err
Rel_ErrID
Rel_Done
Rel_Ex
Axis1
10000.0
3000.0
3000.0
3000.0
3000.0
MC_MoveRelative
Axis Done
Rel
Execute
ContinuousUpdate
Busy
Active
Distance CommandAborted
Error
ErrorIDAcceleration
Deceleration
Jerk
BufferMode
Velocity
TON
EN
In
PT
ENO
Q
ET
TON1
True
Rel_Ex
T#3s
SR
EN
SET
Reset
ENO
Q
SR
SetPos_Ex
Axis1
True
SetPos_Ex
5000.0
0
SetPos_Bsy
SetPos_Done
SetPos_Err
SetPos_ErrID
MC_SetPosition
Axis Done
SetPos
Execute
Position
Busy
Error
Relative
ReferenceType
ErrorID
1
ExecutionMode