EasyManuals Logo

Delta DVP-15MC Series User Manual

Delta DVP-15MC Series
972 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #830 background imageLoading...
Page #830 background image
DVP-15MC Series Motion Controller Operation Manual
11-360
2. See the entire motion process after the instruction is executed.
X
Z
Y
50000
60000
70000
20000
20000
20000
A
B
3. X axis-Y axis-Z axis Motion Curve and Timing Chart
Position
T
DMC_MoveLinearRelative0
LINREL_Exe
LINREL_Abt
LINREL_Done
LINREL_Err
LINREL_Bsy
LINREL_Act
0
20000
Y
X
70000
50000
60000
Z
The start positions of X axis, Y axis and Z axis are all 20,000. LINREL_Dis[1], LINREL_Dis[2] and
LINREL_Dis[3] of DMC_MoveLinearRelative are set to 30,000, 40,000 and 50,000 respectively.
When LINREL_Ex changes to TRUE, LINREL_Bsy changes to TRUE. Two cycles later, LINREL_Act
changes to TRUE and the axes group starts to run.
X axis, Y axis and Z axis reach respecitve target positions simultaneously, LINREL_Done changes
to TRUE and LINREL_Bsy and LINREL_Act change to FALSE when the execution of
DMC_MoveLinearRelative instruction is completed.