Chapter 13
| Basic Administration Protocols
Simple Network Management Protocol
– 427 –
Figure 259: Showing SNMP Views
To add an object identifier to an existing SNMP view of the switch’s MIB database:
1. Click Administration, SNMP.
2. Select Configure View from the Step list.
3. Select Add OID Subtree from the Action list.
4. Select a view name from the list of existing views, and specify an additional OID
subtree in the switch’s MIB database to be included or excluded in the view.
5. Click Apply
Figure 260: Adding an OID Subtree to an SNMP View
To show the OID branches configured for the SNMP views of the switch’s MIB
database:
1. Click Administration, SNMP.
2. Select Configure View from the Step list.
3. Select Show OID Subtree from the Action list.
4. Select a view name from the list of existing views.

Table of Contents