EasyManua.ls Logo

GE P24DM - Figure 154: Automatic Selection of Disturbance Record - Method 1

GE P24DM
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
V01004
Start
Read status word from
r
egister 3x0001
Is disturbance bit
(
bit 4) set?
Select next oldest non-
e
xtracted record by writing
0x04 to register 4x00400
Send command to accept
r
ecord by writing 0x08 to
register 4x00400
Extract disturbance data
Yes
No
Error
Figure 154: Automatic selection of disturbance record - method 1
Method 2
Method 2 is more complex to implement but is more efficient at extracting large quantities of disturbance records.
This may be useful when the disturbance recorder is polled only occasionally and therefore may have many stored
records.
P24xM Chapter 16 - Communications
P24xM-TM-EN-2.1 343

Table of Contents