EasyManua.ls Logo

GE P24DM - Page 489

GE P24DM
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P24xM
Appendix A - Ordering Options
Variants Order Number
1 - 4 56789101112-131415
Model T
y
pe
Motor Protection IED - Directional P24D
Application
Motor M
Small Generator G
Load / Line Mana
g
ement L
Current transforme
r
Standard Earth CT 1
SEF CT 2
Hardware Options
EIA RS485/IRIG-B
(
demodulated
)
20TE/30TE 1
EIA RS485/IRIG-B
(
demodulated
)
and Ethernet - Sin
g
le channel Fibre/Copper
(
settin
g
confi
g
urable as Failover*
)
30TE 6
EIA RS485/IRIG-B
(
demodulated
)
and EIA RS485 30TE 8
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Copper Ethernet - 2x RJ45 Copper
(
settin
g
confi
g
urable as Failover
)
30TE/40TE
A
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
settin
g
confi
g
urable as Failover
)
30TE/40TE B
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Copper Ethernet - 2x RJ45 Copper
(
settin
g
confi
g
urable as RSTP
)
30TE/40TE C
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
settin
g
confi
g
urable as RSTP
)
30TE/40TE D
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Copper Ethernet - 2x RJ45 Copper
(
settin
g
confi
g
urable as PRP or HSR
)
30TE/40TE E
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
settin
g
confi
g
urable as PRP or HSR
)
30TE/40TE F
40TE onl
y
- EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Copper Ethernet - 2x RJ45 Copper
(
settin
g
confi
g
urable as Failover
)
40TE G
40TE onl
y
- EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
settin
g
confi
g
urable as Failover
)
40TE H
40TE onl
y
- EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Copper Ethernet - 2x RJ45 Copper
(
settin
g
confi
g
urable as RSTP
)
40TE J
40TE onl
y
- EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
settin
g
confi
g
urable as RSTP
)
40TE K
40TE onl
y
- EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Copper Ethernet - 2x RJ45 Copper
(
settin
g
confi
g
urable as PRP or HSR
)
40TE L
40TE onl
y
- EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
settin
g
confi
g
urable as PRP or HSR
)
40TE M
EIA RS485/IRIG-B
(
demodulated
)
and Dual Copper Ethernet - 2x RJ45 Copper
(
dual IP
)
30TE/40TE N
EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
dual IP
)
30TE/40TE P
EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Copper Ethernet - 2x RJ45 Copper
(
dual IP
)
40TE Q
EIA RS485, EIA RS485/IRIG-B
(
demodulated
)
and Dual Redundant Fibre Ethernet - 2x multimode fibre
(
dual IP
)
40TE R
I/O Options Case
Standard
(
8 lo
g
ic inputs + 8 rela
y
outputs
)
20TE/30TE
A
Total
(
11 lo
g
ic inputs + 12 rela
y
outputs
)
30TE/40TE B
Total
(
11 lo
g
ic inputs + 12 rela
y
outputs
)
suitable for trip circuit supervision 30TE/40TE C
Total
(
13 lo
g
ic inputs + 12 rela
y
outputs
)
30TE/40TE D
Total
(
3 lo
g
ic inputs + 4 rela
y
outputs
)
20TE E
Total
(
6 lo
g
ic inputs + 8 rela
y
outputs
)
suitable for trip circuit supervision 30TE F
Total
(
10 lo
g
ic inputs + 12 rela
y
outputs
)
suitable for trip circuit supervision 40TE H
Total
(
12 lo
g
ic inputs + 12 rela
y
outputs
)
suitable for trip circuit supervision 40TE J
Communication protocol
Courier 1
Modbus 2
IEC60870-5-103
(
VDEW
)
3
DNP3.0 4
IEC 61850 over Ethernet and Courier via rear RS485 6
IEC 61850 over Ethernet and IEC60870-5-103 via rear RS485 7
DNP3.0 over Ethernet and Courier via rear RS485 8
IEC 61850 over Ethernet and Modbus via rear RS485 9
IEC 61850 over Ethernet and DNP3.0 via rear RS485
A
IEC61850 over Ethernet + DNP3.0 over Ethernet and Courier via RS485 B
IEC61850 over Ethernet + DNP3.0 over Ethernet and Modbus via RS485 C
IEC61850 over Ethernet + DNP3.0 over Ethernet and IEC60870-5-103 via RS485 D
Case
20TE Flush
(
no function ke
y
s, 4 pro
g
rammable LEDs
)
B
30TE Flush
(
3 function ke
y
s with LEDs, 8 pro
g
rammable LEDs
)
C
40TE Flush
(
3 function ke
y
s with LEDs, 8 pro
g
rammable LEDs
)
D
Software onl
y
0
20TE Flush
(
Adapted field volta
g
e for KCGG retrofit
)
2
20TE Flush
(
without field volta
g
e
j
umperin
g
for KCGG retrofit
)
4
30TE Flush
(
Additional shortin
g
link
)
6
Lan
g
ua
g
e
Multilin
g
ual
(
En
g
lish, French, German, Spanish
)
0
Multilin
g
ual
(
En
g
lish, Russian, Italian, Portu
g
uese
)
6
Chinese, En
g
lish or French via HMI, with En
g
lish or French onl
y
via Communications port C
Software Reference
Unless specified the latest version will be delivered **
Customisation / Re
g
ionalisation
Default 0
Customer specific
A
Hardware desi
g
n suffix
Initial release
A
P24xM-TM-EN-2.1
A1

Table of Contents