-112 Program mnemonic too long
A command header contains more than 12
characters:
OUTP:SYNCHRONIZATION ON
-113 Undefined header
An undefined header was encountered. The header
is syntactically correct. Example: the header contains
a character mistake.
SOUR1:AMM:DEPT MIN
-123 Exponent too large
Numeric exponent exceeds 32,000. Example:
SOURce[1|2|3]:BURSt:NCYCles 1E34000
-124 Too many digits
The mantissa (excluding leading 0’s) contains more
than 255 digits.
-128 Numeric data not allowed
An unexpected numeric character was received in
the command. Example: a numeric parameter is
used instead of a character string.
SOURce1:BURSt:MODE 123
-131 Invalid suffix
An invalid suffix was used. Example: An unknown
or incorrect suffix may have been used with a
parameter.
SOURce1:SWEep:TIME 0.5 SECS
-138 Suffix not allowed
A suffix was used where none were expected.
Example: Using a suffix when not allowed.
SOURce1:BURSt: NCYCles 12 CYC
-148 Character data not allowed
A parameter was used in the command where not
allowed. Example: A discrete parameter was used
where a numeric parameter was expected.
SOUR1:MARK:FREQ ON

Table of Contents

Other manuals for GW Instek MFG-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek MFG-2000 Series and is the answer not in the manual?

GW Instek MFG-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelMFG-2000 Series
CategoryInverter
LanguageEnglish

Related product manuals