Interfaces | Ethernet, CAN, RS-232 |
---|---|
Resolution | 24-bit |
Input Voltage Range | ±10 V |
Input Types | Voltage, current |
Operating Temperature | +50 °C |
Device compliance with EMC product standard EN 61326-1:2013 for emission and immunity.
Explanation of CE mark, statutory waste disposal, and electrostatic sensitive device markings.
Definition of symbols used for DANGER, WARNING, CAUTION, Notice, Important, and Tip.
Explanation of IP rating for housings against contact and moisture.
Overview of the complete documentation for the MGCplus system.
Modular system structure, digital data processing, and internal bus communication.
Description of device layout including power supply, communication processor, and amplifier modules.
Details on available housing versions for MGCplus system, including dimensions and slots.
Table illustrating compatible combinations of amplifier and connection boards.
Step-by-step instructions for installing the CP52 communication processor.
Precautions for device installation regarding moisture, temperature, and ventilation.
Guidance on cleaning the housing and handling maintenance-free devices.
Instructions for mains connection and grounding switch configuration.
Principles of electromagnetic compatibility and HBM Greenline shielding design.
Detailed instructions for connecting various transducer types via different connection boards.
Procedure for connecting CANHEAD modules using ML74B card and AP74 board.
Description of digital inputs/outputs of CP52 and analog outputs on the front panel.
Steps for system assembly, component installation, and initial power-up.
Overview of keys and functions on the AB22A display and control unit.
Explanation of initial display, measuring mode displays, and error messages.
Detailed guide on navigating and configuring settings in Setup mode.
Introduction to measurement procedures and adjustment steps.
Steps for adjusting measurement channels, including transducer-specific settings.
Specific procedures for adapting various transducer types to the amplifier.
Configuration of selectable signals, numeric values, graphs, and limit value status.
Explanation of F keys functionality in measuring and setup modes.
Procedure for assigning descriptive names to channels for identification.
Setting up password protection and access authorization for users.
Instructions for saving, loading, and copying system settings and parameters.
Configuration of measurement recording, including parameters, triggers, and file formats.
Configuration of device address, subnet mask, DHCP, and communication protocols.
Function to select the language for display, menus, and texts.
Setting the date, day of the week, and time for the device.