Connection
Strain gage half bridges on AP815i
MGCplus A0534-30.0 HBM: public 47
4.3.7 Strain gage half bridges on AP815i
14
1
2
3
16
Hsg.
17
4
5
6
19
20
7
8
9
22
23
10
11
12
25
Hsg.
Hsg. Hsg.
AP815i
13
14
25
Subchannel
1...4
Subchannel
1/5
Subchannel
2/6
Subchannel
3/7
Subchannel
4/8
1
13
14
25
1
1
2
Measurement signal (+)
1)
Bridge excitation voltage (+)
Sense lead (-)
Sense lead (+)
Bridge excitation voltage (-)
Cable shield
Measurement signal (-)
1)
wh/gn
wh/rd
br
gn
wh/br
rd
4
Subchannel
5...8
15
18
21
24
3
AP815i can measure decentralized half bridge circuits for which the active
SGs are separated by a line.
1)
With decentralized half bridge circuits the measured value must be acquired at both ends of the connecting line between the active SGs.
With standard half bridge circuits a connector can also be bridged.