Introduction
Installation of the CP52 communication processor
26 A0534-30.0 HBM: public MGCplus
3.7 Installation of the CP52 communication processor
For type "D" housings (ER003D or TG001D, etc.) the existing communica
tion processor (CP22/CP42) can be replaced by the CP52 communication
processor.
► Loosen the screws on the old communication processor, the blind panel
(only with CP22) and the cover of the NT030 power supply unit.
► Remove the parts.
► Insert the new CP52 communication processor and screw it in place.
► Fit the power supply cover of the NT030 and screw the cover in place.
The process is similar when subsequently installing a CP52 communication
processor in an MGCplus housing (type "D" or type "E") that was initially
configured without a communication processor.
► Loosen the screws on the blind panels, if there are any, of the SY03 syn
chronization interface and the power supply cover.
► Remove the parts.
► Insert the new CP52 communication processor and screw it in place.
► Fit the power supply cover of the NT030 or NT040 and screw the cover
in place.