EasyManua.ls Logo

Hioki IM3536 - Default Chapter; Table of Contents

Hioki IM3536
276 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Contents
i
When measuring conductivity and
permittivity ...................................................67
3.5 Judging Measurement Results ..... 68
Setting the judgment mode ......................... 69
Conguring comparator function
settings (judging measurement results
based on one judgment standard) ..............69
Conguring BIN function settings
(judging measured values based on
multiple judgment standards) ......................74
3.6 Setting Application Settings ......... 79
Range synchronization
(Setting measurement conditions for
individual measurement Ranges) ...............79
Waveform averaging function
(increasing measurement precision or
measurement speed) .................................. 82
High-Z reject function (detecting contact
errors during 2-terminal measurement) ......84
Contact check function
(
detecting poor contact with the sample
during 4-terminal measurement) .................85
Memory function
(saving measurement results) ....................86
Number of effective digits of the
measurement value ....................................87
LCD display auto-off (power-saving mode) 88
Key tones and judgment tones ...................89
Key-lock function (Disabling key operation) 90
4 Using Continuous
Measurement Mode 93
4.1 Setting Which Panels to Use in
Continuous Measurement ............. 93
4.2 Performing Continuous
Measurement .................................. 94
4.3 Checking Continuous
Measurement Results .................... 94
4.4 Changing the Display Timing
Setting
(When You Wish to Shorten the
Screen Update Interval) ................. 95
4.5 Setting the LCD display auto-off
(When You Wish to save the
power) ............................................. 96
5 Error Correction 97
5.1 Setting the Cable Length
(Cable Length Correction) ............. 98
5.2 Open Correction ............................. 99
Before performing open correction .............99
All correction .............................................100
Contents
Introduction ................................................ 1
Verifying Package Contents ..................... 1
Measurement process............................... 6
Safety Information ................................... 10
Operating Precautions ............................ 12
1 Overview 17
1.1 Product Overview and Features ... 17
1.2 Names and Functions of Parts ..... 18
1.3 Screen Layout and Operation ....... 20
Screen transition diagram ........................... 20
Viewing measured values
(Measurement screen) ................................22
Select the measurement mode
(MODE screen) ........................................... 24
Setting detailed settings such as
measurement conditions (SET screen) ......25
Checking measurement condition
settings information .....................................26
Conguring correction functionality
(ADJ screen) ............................................... 27
Conguring the instrument’s interfaces,
setting the time and date, and checking
the system (SYS screen) ............................28
Displaying and manipulating les on the
USB ash drive (FILE screen) ....................29
2 Measurement
Preparations 31
2.1 Preparation Flowchart ................... 31
2.2 Pre-Operation Inspection .............. 33
2.3 Connecting the Power Cord .......... 34
2.4 Connecting the Measurement
Cables, Probes, or Fixture ............. 35
2.5 Turning the Power On and Off ...... 36
2.6 Setting the Date and Time ............. 38
3 Performing Measure-
ments in LCR Mode 39
3.1 Setting Display Parameters ........... 39
To perform DC measurement
(DC resistance measurement) .................... 40
3.2 Viewing Measured Values.............. 41
3.3 Enlarging Display of
Measurement Values ...................... 42
3.4 Setting Measurement
Conditions (basic settings) ........... 43
Required settings ........................................ 44
User-congurable settings ..........................54
Measurement and data acquisition timing ..65
IM3536A981-02
3
2
1
5
4
Ind.Appx.
10
9
8
7
6

Table of Contents

Related product manuals