your recorder. The example on the next page will help you to decode the model.
Input Actuation (Note 1)
D R 4 5 A 00
0
1
3
=
=
=
None
T/C, RTD, Radiamatic, mV, 0–5V, 4–20mA
0–10 Vdc
External Output
0 0
1 0
1 1
4 0
4 4
5 0
6 0
6 6
= None
= 1 Control Output
= 2 Control Outputs
= 1 Control w/SP Programming
= 2 Controls w/SP Programming
= Pulse Output
= 1 Control Output with FM Approval
= 2 Control Outputs with FM Approval
Table 1 Table 2 Table 3 Table 4 Table 5Key Number
Hardware Options
0 - - - - -
1 - - - - -
E - - - - -
F - - - - -
5 - - - - -
6 - - - - -
Software Options
0
A
B
E
F
H
K
L
M
= None
= Totalization, Input 1
= Math Only
= Totalization, Inputs 1 & 2
= Fo Sterilization Calculation
= Totalization, Inputs 1, 2, 3, & 4
= Totalization, Input 1 + Math
= Totalization, Input 1 and 2 + Math
= Totalization, Input 1, 2, 3, 4 + Math
– – – – – –
Table 6
Key Number
T
R
W
H
P
S
=
=
=
=
=
=
Standard Recorder
Relay expansion Recorder
Flow Recorder
HTST
Pasteurization Recorder - Flow
Safety Thermal Limit Recorder
NOTE 1:
Every DR4500A recorder has all the available inputactuations stored in its nonvolatile memory
and can accept up to 4 inputs which must be specified sequentially in 1–4 entries in Table 1.
Therefore, you can easily change the input actuation in the field by re-wiring input connections,
changing the input jumper position, and reconfiguring the input type, as applicable.
Gray door / Glass window
Gray door / Acrylic window
Gray door / Glass window and keypad
Gray door / Acrylic window and keypad
Blue door / Glass window
Blue door / Acrylic window
External Interface
0 – –
1 – –
3 – –
4 – –
– 0 –
– 1 –
– – 0
– – 1
– – 2
– – 3
– – 4
= None
= Auxiliary 4-20 mA Output
= RS485 Modbus RTU**
= RS485 Modbus RTU** plus Auxiliary Output
= Standard Pen
= Abrasion Resistant Pen
= None
= 2 Alarm Outputs/2 Digital Inputs
= 4 Alarm Outputs/2 Digital Inputs
= 6 Alarm Outputs/2 Digital Inputs
= 1 Alarm/1 Timer/2 Digital Inputs **
**Only available with key number DR45AT, AR, AW
=
=
=
=
=
=
L - - - - -
9 - - - - -
Black door / Glass window
Black door / Acrylic window
=
=
P - - - - -
R - - - - -
S - - - - -
NEMA4X door / Glass window
NEMA4X door / Acrylic window
NEMA4X HTST door
=
=
=
- 0 - - - -
- A - - - -
- K - - - -
- - 0 - - -
- - L - - -
- - M - - -
- - N - - -
- - - 0 - -
- - - K - -
- - - L - -
- - - M - -
- - - N - -
- - - P - -
Standard door latch
Keyed latch
Door lock with key
No illumination
Configuration lockout / Chart plate seal
Configuration Lockout / Chart plate seal / Illumination
Chart illumination
No approvals
CE Mark
CE Mark + UL + CSA certification
CE Mark + FM approval
CE Mark + UL + FM / CSA certification
UL listing + CSA certification
=
=
=
=
=
=
=
=
=
=
=
=
=
- - - R - - FM approved - Class 1, Div. 2, Groups A, B, C, D
=
- - - U - -
- - - - 0 -
- - - - T -
- - - - B -
- - - - C -
- - - - D -
- - - - E -
- - - - - 0
- - - - - 1
UL listing + CSA certification + FM approval
No I.D. Tag
Customer I.D. Tag (30 characters maximum)
Certificate of Conformance (F3391)
Custom Calibration / Test Report (F3399)
Certificate of Conformance + I.D. Tag
Customer Calibration + I.D. Tag
None
Product Configuration
=
=
=
=
=
=
=
=
=
1 = 1 Pen Recorder
2 = 2 Pen Recorder