Intel® Server System S7000FC4UR TPS BIOS User Interface
Revision 1.0
181
Setup Item Options Help Text Comments
Reset on Fatal Error Enabled
Disabled
[Enabled] – System will trigger a
reset on fatal errors.
[Disabled] – System will trigger a
Non-Maskable Interrupt on fatal
errors.
The system normally generates
a NMI in response to fatal errors
at runtime. The operating
system typically halts the system
in response to NMI thereby
containing potential data
corruption.
The user can configure this
option to Enabled for Operating
Systems that do not respond to
an NMI with a system halt. This
ensures the corrupted data is
contained by the reset.
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
BIOS programs the BMC watchdog
timer for approximately 6 minutes. If
BIOS does not complete POST
before the timer expires, the BMC
will reset the system.
OS Boot Watchdog
Timer
Enabled
Disabled
BIOS programs the watchdog timer
with the timeout value selected. If
the OS does not complete booting
before the timer expires, the BMC
will reset the system and an error is
logged.
Requires OS support or Intel
®
System Management Software.
OS Boot Watchdog
Timer Policy
Power Off
Reset
If the OS watchdog timer is
enabled, this is the system action
taken if the watchdog timer expires.
[Reset] – System performs a reset.
[Power Off] – System powers off.
OS Boot Watchdog
Timer Timeout
5 minutes
10 minutes
15 minutes
20 minutes
If the OS watchdog timer is
enabled, this is the timeout value
BIOS will use to configure the
watchdog timer.
Console Redirection View/Configure console redirection
information and settings.
Takes user to Console
Redirection screen.
System Information View system information. Takes user to System
Information screen.
Intel
®
Remote
Management Module
Information
View Intel
®
RMM2 information. Takes user to Intel
®
Remote
Management Module
Information screen.
This menu item should be
suppressed if the I/O riser board
is not installed.

Table of Contents

Other manuals for Intel S7000FC4UR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel S7000FC4UR and is the answer not in the manual?

Intel S7000FC4UR Specifications

General IconGeneral
BrandIntel
ModelS7000FC4UR
CategoryServer
LanguageEnglish

Related product manuals