EasyManuals Logo

JVL MIS23 Series User Manual

JVL MIS23 Series
347 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #136 background imageLoading...
Page #136 background image
134 JVL Industri Elektronik A/S - User Manual - Integrated Stepper Motors MIS23x, 34x, 43x
8.2 MIS23x Registers
8.2.42 Encoder_Typ
8.2.43 Afzup_WriteBits
Description: When changing values for the analogue input filter parameters, this register is used in
combination with registers 102-106. First, all of the registers 102-106 must be loaded
with the values to be used for one or more analogue input filters.
Then the lower eight bits in this register are set to select which inputs the parameters in
registers 102-106 should control. The firmware will detect this and copy the parameter
values from registers 102-106 to internal storage. Once this has been completed, the
firmware sets bit 15 in this register to show that registers 102-106 are free to receive
new values for programming the remaining inputs with other filter parameters. To use
the same filtering for all analogue inputs, this register can be loaded with 255 (hex FF).
8.2.44 Afzup_ReadIndex
Description: This register makes it possible to read back the analogue input filter parameters for one
analogue input at a time. To select a new input, write a value of 1 to 8 to this register and
wait for bit 15 to be set high.
When bit 15 has been set by the firmware, the registers 102-106 have been loaded with
the filter parameters currently used by that analogue input.
8.2.45 Afzup_ConfMin
Description: The minimum confidence limits for analogue inputs are set and read back using this reg-
ister in combination with the read and write ‘command’ registers 100 and 101.
If a new raw sample value is less than the value in this register, it is simply discarded and
the filtered input value in registers 81-88 will not change. A value of zero in this register
will effectively disable the minimum confidence check.
Reg Name Size Access Range Default Unit MacTalk name
99 ENCODER_TYPE 16bit R 0-10 - - “Tooltip on motor”
Reg Name Size Access Range Default Unit MacTalk name
100 AFZUP_WriteBits 16bit R/W - 0 Special
N/A handled on the
Filter Setup screen
Reg Name Size Access Range Default Unit MacTalk name
101 AFZUP_Read Index 16bit R/W
0, 1-8,
32768-
32775
0 Special
N/A handled on the
Filter Setup screen
Reg Name Size Access Range Default Unit MacTalk name
102 AFZUP Conf Min 16bit R/W 0-1022 0 4.888 mV Confidence Min