Info centre "EasyTouch"
201
Graphical representation of AutoScan sensor settings in expert mode
The ex-works default values for minimum and maximum degree of maturity can only be
changed in expert mode. By changing the percentage values, you are influencing the ability of
the AutoScan to detect colour.
• To switch to expert mode, set parameter 34020 to the value 1 in the menu "AutoScan".
Fig. 145
Theoretical maximum chop length at 100% degree of maturity. However, the chop
length is not further increased above approx. 66% degree of maturity as a degree of
maturity greater than 66% is unlikely to occur in practice.
Theoretical minimum chop length at 0% degree of maturity. However, the chop
length is not further reduced below approx. 33% degree of maturity as a degree of
maturity below approx. 33% is unlikely to occur in practice.
Currently determined degree of maturity. If the display remains at 50%, the sensor
does not detect a valid maturity.
The current position on the characteristic curve within the working range.
The minimum chop length set by the user, which can be changed using the and
keys. The associated degree of maturity (8) can be changed using the
keys or the incremental encoder.
The maximum chop length specified by the user, which can be changed using the
and keys. The associated degree of maturity (9) can be changed using the
and keys or the incremental encoder.