8.6.5.2 Row tracer calibration
5
6
7
8
B
C
D
BX500661_2
5 6
7
8
B C D
BX500058
Fig. 210
The row tracers must be calibrated if the sensors B61, B65, B66 of the row tracers have been
replaced.
The row tracers in the central tip or the outer tips can be chosen.
In the mask "Parameter", group automatic steering system, choose the parameter 34016
"automatic steering system row tracers in central tip":
0 = Outer tip
1 = Central tip
Calibrating row tracers with steel bracket
In menu 1-1-14, set parameter 26025 in the group automatic steering system "Flexible row
tracer fitted" to the value 0.
Prerequisites:
The row tracers are in the basic position and are not actuated.
NOTE
Both row tracer right/left are calibrated on a once-off basis.