8.6.4.2 Calibrating the absolute cutting height
Calibration of the absolute cutting height is required to ensure the absolute cutting height can be
indicated in the info centre.
The calibration values are stored separately for Pick-up, XDisc and maize header.
To calibrate the absolute cutting height, the sensors at the lifting unit must be calibrated in
advance, see page 302.
Measuring the lifting height
Pick-up
Fig. 201
Measure the distance "a" between the ground and the lowest point of a spring tine.
Maize header EasyCollect
Fig. 202
Measure the distance (a) between the ground and the cutter blade.
XDisc
Fig. 203
Measure the distance "a" between the ground and the blade.