8.16 Calibration of the internal silage additives unit
The silage additives unit should be calibrated prior to each use in order to obtain maximum
precision.
Notice
Prior to every calibration, fill the silage additives unit with tanked silage additives up to the
nozzle by manually controlling the silage additives pump in continuous operation.
CAUTION!
If used improperly, the chemicals used in the silage additives unit may cause damage to health.
• The safety instructions issued by the silage additives manufacturer must be followed.
Fig. 336
1. Switch off the silage additives unit by pressing the
(
) key.
2. Remove the quick coupling from the hose of the silage additives unit.
3. Switch on continuous operation (see chapter "Continuous operation") and leave switched
on until liquid runs out of the quick coupling.
4. Press the (
) key to switch off the silage additives unit.
5. During calibration, collect the liquid in a measuring cup (min. 2 litres).
6. Start the calibration by pressing the ( ) key. Use a measuring cup to collect the
liquid running out of the quick coupling.
The calibration process stops automatically as soon as the progress bar (2) has reached
100%.
7. In the displayed field (1) enter the silage additives quantity collected in the measuring cup in
millimetres and confirm by pressing the rotary potentiometer. The calibration is now
complete.
Notice
The calibration can be cancelled at any time by pressing the
(