Maintenance - Gearbox
730
26.1.6 Maintenance worm drive
Oil level check
Fig. 686
Thoroughly clean the area around the oil level inspection screw (4).
Dismount the oil level inspection screw (4).
Oil level must reach the inspection bore, if necessary, top up oil (see Oil change).
Re-mount the oil level inspection screw (4).
Oil change
Remove the cover plate (1).
Thoroughly clean the area around the oil drain plug (2) and the ventilation filter (3).
Dismount the ventilation filter (3).
Provide a collecting vessel (10 litres).
Dismount the oil drain plug (2) and drain the oil.
Re-attach the oil drain plug (2).
CAUTION! Damage to the gearbox! The gearbox may be damaged if a mixture of different oils
is used.
Add the oil. Type of oil and filling quantity, see page 104.
Mount the ventilation filter (3).
Attach the cover plate (1).