Info centre "EasyTouch"
264
8.6.4 Menu 3-3 Calibration of absolute lifting unit height
Fig. 198
Main menu 3 Maintenance is active.
• Using the incremental encoder, choose menu 3-3 Calibration of absolute lifting unit height.
• Press the incremental encoder.
The display shows the menu level Calibration of absolute lifting unit height.
Displays on the display:
Displaying the current lifting height in %.
Display of the current saved absolute height of the lifting unit at 80 %.
Display of the current saved absolute height of the lifting unit at 20 %
The absolute lifting unit height must be calibrated if
• the "KMC3" control unit was replaced,
• the terminal was replaced,
• the lifting unit control was replaced,
• valves on the valve block "working hydraulics" were replaced,
• sensors (B25, B47, B48, B49, B50, B55, ) were replaced,
• if the front attachment was replaced.
Displaying unfulfilled switching-on conditions and disturbances, see page 255.