Maintenance - Gearbox
728
26.1.4 Maintenance of angular gearbox
NOTE
Check oil level and change the oil when the feed drive housing cover is in a horizontal position.
Oil level check
Machine no. 83 3001-879999 Oil le vel check
Fig. 684
Thoroughly clean the area around the oil dip stick (1).
Unscrew the oil dip stick (1) and remove any oil residue using a lint-free, clean cloth.
Screw in the oil dip stick (1) and unscrew it again.
Read the oil level.
The oil level must be between the markings "MIN" and "MAX", if necessary top up oil
(see Oil change).
Screw in the oil dip stick again.
Oil change
Provide a collecting vessel (approx. 5 litres).
Thoroughly clean the area around the oil drain plug (2).
Dismount the oil drain plug (2) and drain the oil.
Unscrew the oil dip stick.
Re-attach the oil drain plug (2).
Add the oil. Type of oil and filling quantity, see page 104.
Screw in the oil dip stick again.