Maintenance compressed air system
655
23 Maintenance compressed air system
WARNING
Risk of injury from escaping compressed air.
The compressed air system is under high pressure. Escaping compressed air may seriously
injure skin, limbs and eyes.
Shut down and safeguard the machine, see chapter Safety, "Shutting down and
safeguarding the machine".
Relieve the pressure in the compressed air system.
23.1 Compressed-air reservoir
WARNING
Risk of injury from corroded or damaged compressed air reservoirs.
Damaged or corroded pressure vessels may burst and cause serious injuries.
Observe the inspection intervals according to the maintenance table, see chapter
Maintenance-Engine "Maintenance table".
Have damaged or corroded compressed air reservoirs replaced immediately by a service
centre.
1
BX770161
2
Fig. 578
Condensation forms in the compressed air storage tank (1). The condensation water can lead to
malfunctions.
Drain condensation water
Switch off diesel engine.
Depressurise the compressed air storage tank (via a blow-out gun).
Use the drain valve (2) to drain the condensation water collected in the compressed air
storage tank (1) into a suitable container.
Checking the compressed air reservoir
Have the interior area of the compressed air reservoir checked in accordance with national
requirements. A check is recommended at intervals of 2 years.
Check the tensioning straps on the compressed air storage tank are secure. If necessary,
tighten using the nuts.