17.3 Jump starting the machine
CAUTION!
Damage to the machine by connecting the jump-start battery to the starter
If the jump-start battery for jump-starting the machine is connected to the starter, the starter
and the battery will be damaged.
Never connect the jump-start battery to the starter.
NOTICE
When using jump start batteries with a voltage of 12 V, first connect the jump start batteries
in series (24 V)
When using a charging device (24V), which has a jump start function, it must be switched
off before it is connected and disconnected.
Connecting jump start voltage source
12 V
G1 12 V
24 V
G2 12 V
24 V
12 V
G4
Fig. 463
NOTICE
Always connect the batteries of the machine last in order to avoid machine damage.
Dismount the pole protection caps from the positive poles of the batteries.
Connect the positive poles of the battery and the jump start voltage source in succession.
Connect the negative terminals of the battery and the external start voltage source in
succession.
Disconnecting jump start voltage source
NOTICE
Always disconnect the batteries of the machine first in order to avoid machine damage.
Disconnect the negative poles of the battery and the jump start voltage source in
succession.
Disconnect the positive poles of the battery and the jump start voltage source in succession.
Mount the pole protection caps on the positive poles of the batteries.