8.6.9 Menu 3-9 Calibration of RockProtect
The nominal value of the sensor is 2500 mV. This value may deviate slightly due to component
tolerances.
The zero position of the sensor must always be calibrated if
– the sensitivity of the sensor is too strong or too weak.
– the sensor B76, KMC4 or cable harness/plug has been replaced.
– the saved value and the currently measured value deviate too greatly from each other.
Fig. 227
Prerequisites:
– KMC2: There must be no error message from the CAN bus.
– KMC4: There must be no error message from the CAN bus.
– The machine is switched off.
Main menu 3 Maintenance is active.
• Using the incremental encoder, choose menu 3-9 "Calibration of RockProtect".
• Press the incremental encoder.
The display shows menu level Calibration of RockProtect.
• Press the
key under to start the calibration.
The current voltage value is saved.