Info centre "EasyTouch"
247
Menu 1-7-5 "Configure status line" is active.
You can use the incremental encoder to select the display
, the input field is
highlighted in colour.
Press the incremental encoder to confirm your selection.
BX851054
Fig. 183
If the NIR sensor is active, the working screen displays the current moisture value (1) of the
crop.
To ensure that the NIR sensor provides correct values, you must set the type of crop.
Select menu 1-1-25 "Moisture measurement".
Set the parameter 30044 "Type of crop". Value 16 = Maize, Value 32 = Grass,
Value 0 = User-defined.
The NIR sensor is active if the following conditions are fulfilled:
After being installed for the first time, the NIR sensor is released by a technician.
The NIR sensor is activated. To do this, set the parameter 34019 "Moisture measurement
type" to the value "2" (NIR sensor) in the menu 1-1-25 "Moisture measurement".
The machine is in the XPower operating mode (optimum measurement results are only
obtained in this mode).
The spout should ideally be fully raised to optimise the function of the NIR sensor.
The release switch maintenance is switched off.
The main coupling is switched on.
The feed drive/front attachment is switched on.
The lifting unit is in working position.
The setpoint engine rotational speed is greater than 1500 rpm (fixed value, cannot be
changed).
The machine load is greater than 60%.