Display 2 “Actuator test”
Fig. 240
On display 2 "Actuator test" the function of the actuators associated with the front attachment
can be tested.
Mask description display 2 "Actuator test"
Screen display/icons/description
D606 front attachment current
Front attachment forwards
Front attachment backwards
D614 KMC2 load voltage 12V1
Supply voltage +12V1 for the outputs of the KMC2 in mV.
Switching actuators on/off
If all switching-on conditions for the actuator test are fulfilled,
and are displayed and
the actuators displayed are released. These can be switched on and off using the numerical
keys.
Front attachment forwards
Front attachment backwards