Info centre "EasyTouch"
429
Speed-dependent input:
• Press the
key to select speed-dependent input (1).
• Select the input field for speed reduction (6) by using the incremental encoder. The input
field is highlighted in colour.
• Press the incremental encoder to jump to the input field. The input field is highlighted in
yellow.
• Turn the incremental encoder to the left or right to reduce or increase the degree of speed
reduction from 3% – 20%.
• Press the incremental encoder to accept the setting and to exit the selection box.
Engine load-dependent input:
• Press the key to select the engine load-dependent input (2).
• Using the incremental encoder, select the input field for the nominal load (6). The input field
is highlighted in colour.
• Press the incremental encoder to jump to the input field. The input field is highlighted in
yellow.
• Turn the incremental encoder to the left or right to reduce or increase the degree of speed
reduction from 65% – 95%.
• Press the incremental encoder to accept the setting and to exit the selection box.