Error code Description Action
173.04 LVPS cooling fan under speed or stalled
during speed adjustment state
See “LVPS cooling fan service check” on page 116.
173.05 LVPS cooling fan over speed during speed
adjustment state
See “LVPS cooling fan service check” on page 116.
173.06 LVPS cooling fan capture data is invalid and
speed control is at maximum in fan control
idle state
See “LVPS cooling fan service check” on page 116.
173.07 LVPS cooling fan capture data is invalid and
speed control is at maximum in fan control
adjustment state
See “LVPS cooling fan service check” on page 116.
174.03 HVPS cooling fan took too long to ramp up See “HVPS cooling fan service check” on page 117.
174.04 HVPS cooling fan under speed or stalled
during speed adjustment state
See “HVPS cooling fan service check” on page 117.
174.05 HVPS cooling fan over speed during speed
adjustment state
See “HVPS cooling fan service check” on page 117.
174.06 HVPS cooling fan capture data is invalid
and speed control is at maximum in fan
control idle state
See “HVPS cooling fan service check” on page 117.
174.07 HVPS cooling fan capture data is invalid
and speed control is at maximum in fan
control adjustment state
See “HVPS cooling fan service check” on page 117.
175.03 Miscellaneous cooling fan took too long to
ramp up
See “Miscellaneous cooling fan service check” on page 117.
175.04 Miscellaneous cooling fan under speed or
stalled during speed adjustment state
See “Miscellaneous cooling fan service check” on page 117.
175.05 Miscellaneous cooling fan over speed
during speed adjustment state
See “Miscellaneous cooling fan service check” on page 117.
175.06 Miscellaneous cooling fan capture data is
invalid and speed control is at maximum in
fan control idle state
See “Miscellaneous cooling fan service check” on page 117.
175.07 Miscellaneous cooling fan capture data is
invalid and speed control is at maximum in
fan control adjustment state
See “Miscellaneous cooling fan service check” on page 117.
7463
Diagnostic information