5 Remove the screw (A) securing the sensor.
6 Release the cable from its cable holders, then remove the sensor (pass through).
HCIT media feeder removal
1 Remove the HCIT. See “HCIT removal” on page 576.
2 Remove the drawer assembly rear cover. See “HCIT drawer assembly rear cover removal” on page 580.
3 Remove the drawer assembly left cover. See “HCIT drawer assembly left cover removal” on page 580.
4 Remove the top cover assembly. See “HCIT top cover assembly removal” on page 583.
5 Remove the sensor (roller position). See “Sensor (pick roll position) removal” on page 589.
7463
Repair information
592