EasyManua.ls Logo

Lexmark MX81 series - HCIT Media Feeder Removal

Lexmark MX81 series
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Remove the screw (A) securing the sensor.
6 Release the cable from its cable holders, then remove the sensor (pass through).
HCIT media feeder removal
1 Remove the HCIT. See “HCIT removal” on page 537.
2 Remove the drawer assembly rear cover. See “HCIT drawer assembly rear cover removal” on page 542.
3 Remove the drawer assembly left cover. See “HCIT drawer assembly left cover removal” on page 543.
4 Remove the top cover assembly. See “HCIT top cover assembly removal” on page 548.
5 Remove the sensor (roller position). See “Sensor (pick roll position) removal” on page 554.
7463
Repair information
557

Table of Contents

Related product manuals