Transfer
This setting controls the transfer roll algorithm.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Transfer
2 Press Back.
Print Contrast
This setting controls the developer voltage offset.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Print Contrast
2 Press OK or touch to save any changes.
Charge Roll
This setting controls the charge roll voltage.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Charge Roll
2 Press OK or touch to save any changes.
Gap Adjust
The setting adjusts the minimum gap between sheets. Increasing this value may reduce curl of some printed media
and eliminate some output bin stacking problems. However, increasing this value also results in slower overall
performance, measured in pages per minute.
The range of values is 0 to 255, and the default value is 0.
To adjust this setting:
1 From the Diagnostics menu, navigate to:
EP Setup > Gap Adjust
2 Press OK or touch to save any changes.
Automatic Darkness Adjust (Auto Dark Adj)
When activated, this setting attempts to optimize the amount of toner used when printing with a specific operating
point.
7463
Service menus
248