Sensor (output pass through) late jam service check
Action Yes No
Step 1
Remove, and then reinstall the output option.
Does the problem remain?
Go to step 2. Problem is solved.
Step 2
Remove obstructions between the base machine and the output
option.
Does the problem remain?
Go to step 3. Problem is solved.
Step 3
Check if the display on the operator panel changes every time the
sensing area of the sensor (output pass through) is interrupted or
blocked.
a Enter the diagnostic mode.
b Select Output bin tests.
c Select Sensor test.
d Select Output bin x.
e Observe the line item “passthru.”
If possible, replace the sensor. Go to
“Sensor (high capacity
stacker pass through) removal” on page 399, “Sensor (5-bin
mailbox pass through) removal” on page 348, or “Sensor
(output expander pass through) removal” on page 428.
Does the problem remain?
Go to step 4. Problem is solved.
Step 4
Check the above sensor for proper connection, and if necessary,
replace the connection.
Does the problem remain?
Go to step 5. Problem is solved.
Step 5
Perform a print test using the output option. If necessary, replace
the output option.
Does the problem remain?
Contact next level of
support.
Problem is solved.
4062
Diagnostic information
157