MAX32660 User Guide
Maxim Integrated Page 45 of 195
4.12.1 System Initialization Register Details
Table 4-27: Function Control Register 0
System Initialization Status Register
Reserved for Future Use
Do not modify this field.
Configuration Error Flag
This field is set by hardware during reset if an error in the device configuration is
detected.
0: Configuration valid.
1: Configuration invalid.
Note: If this field reads 1 a device error has occurred. Please contact Maxim
Integrated technical support for additional assistance providing the address
contained in SIR_ADDR_ER.addr.
Configuration Valid Flag
This field is set to 1 by hardware during reset if the device configuration is valid.
0: Configuration Invalid
1: Configuration Valid
Note: If this field reads 0 the device configuration is invalid and a device error has
occurred. Please contact Maxim Integrated technical support for additional
assistance.
Table 4-28: System Initialization Address Error Register
System Initialization Status Register
Configuration Error Address
If the SIR_STAT.cfg_err field is set to 1, the value in this register is the address of the
configuration failure.
4.13 Function Control Registers
The FCR base peripheral address is 0x4000 0800. Refer to Table 3-1: APB Peripheral Base Address Map for the addresses of
all APB mapped peripherals.
Table 4-29: Function Control Registers, Offsets and Descriptions
Function Control Register 0
4.13.1 Function Control Register Details
Table 4-30: Function Control Register 0
Function Control Register 0
Reserved for Future Use
Do not modify this field.