CHARGING SYSTEM
01–17–2
BATTERY CONSTRUCTION
CHU011701008S03
• Air that passes through the battery duct when the vehicle is moving is used to cool the battery, improving
reliability.
End Of Sie
GENERATOR CONSTRUCTION
CHU011701008S04
• The voltage regulator has been eliminated, and generator control is carried out by the PCM.
End Of Sie
BATTERY DUCT
BATTERY
BATTERY COVER
BATTERY TRAY
BATTERY
BOX
FRONT
INTAKE AIR
CHU0117S002
STATOR COIL
INSTRUMENT
CLUSTER
(WARNING LIGHT)
CAN
B
P
D
POWER TRANSISTOR
BATTERY
PCM
CHU0117S003

Table of Contents