Installation
2-40 Manual # 42-02-2P24
Ovld Time Out Time that defines motor overload curve sec 5.0 - 120.0 60.0 60.0
Flux Sat Break Flux saturation curve slope change point % 0 - 100 75 75
Flux Sat Slope 1 Flux saturation curve slope for low fluxes % 0 - 200.0 0 0
Flux Sat Slope 2 Flux saturation curve slope for high fluxes % 0 - 200.0 50 50
Configure C0
C1 User Switches
Spd Command Src Speed Command Source -
Analog input
Multi-step
Serial multi-step
Serial
Multi-step Serial
Run Command Src Run Command Source - External TB
Serial
Serial+extern
External
TB
Serial
Hi/Lo Gain Src High / low gain change switch source - External TB
Serial
Internal
Internal Internal
Speed Reg Type Chooses speed regulator - Elev spd reg
Pi speed reg
External reg
Elev spd
reg
Elev spd
reg
Motor Rotation Allows user to reverse direction of motor rota-
tion
-Forward
Reverse
Forward Forward
or
Reverse
Spd Ref Release Determines when speed reference release is
asserted
-Reg release
Brake picked
Reg
release
Reg
release
Cont Confirm Src Enables external logic input for contactor con-
firmation.
-None
External TB
None External
TB
Pre Torque Source Enables and determines the source of the pre
torque command
-None
Analog input
Serial
None Serial
Pre Torque Latch Determines if analog pre-torque command is
latched
-Not latched
Latched
Not
latched
Not
Latched
PT torq Latch Clck Determines source of pre torque latch control
(if used)
-External TB
Serial
External
tb
External
TB
Fault Reset Src Fault reset source - External TB
Serial
Automatic
External
tb
Serial
Overspd Test Src Determines external logic source to trigger
overspeed test
-External TB
Serial
External
tb
External
tb
Brake Pick Src If drive controls mechanical brake, determines
source of brake pick command
- Internal
Serial
Internal Internal
Brake Pick Cnfrm Enables a logic input to use for brake pick con-
firmation
-None
External TB
Internal time
None None
Brake Hold Src If drive controls mechanical brake, determines
source of brake hold command
- Internal
Serial
Internal Internal
Ramped Stop Sel Selects normal stop or torque ramp down stop - None
Ramp on stop
None Ramp on
Stop
Table 2.5 Magnetek AC Drive Table
# Display Parameter Description Unit Range Defaults Factory