Installation
2-42 Manual # 42-02-2P24
MLT-SPD to DLY3 Assigns multi-step speed command to recog-
nition delay timer 1
-None
mspd1-
mspd15
None None
MLT-SPD to DLY4 Assigns multi-step speed command to recog-
nition delay timer 1
-None
mspd1-
mspd15
None None
C2 Logic Inputs
Log In 1 TB1-1 Terminal 1 Selection - - DRIVE
ENABLE
DRIVE
ENABLE
Log In 2 TB1-2 Terminal 2 Selection - - RUN CON-
TACT
CFIRM
Log In 3 TB1-3 Terminal 3 Selection - - FAULT
RESET
Log In 4 TB1-4 Terminal 4 Selection - - UP/DWN NO
FUNC-
TION
Log In 5 TB1-5 Terminal 5 Selection - - S-CURVE
SEL 0
NO
FUNC-
TION
Log In 6 TB1-6 Terminal 6 Selection - - STEP REF
B0
NO
FUNC-
TION
Log In 7 TB1-7 Terminal 7 Selection - - STEP REF
B1
NO
FUNC-
TION
Log In 8 TB1-8 Terminal 8 Selection - - STEP REF
B2
NO
FUNC-
TION
Log In 9 TB1-9 Terminal 9 Selection - - EXTERN
FAULT 1
NO
FUNC-
TION
C3 Logic Outputs
Log Out 1 tb1-14 Terminal 14 Selection - - READY
TO RUN
Log Out 2 tb1-15 Terminal 15 Selection - - RUN COM-
MAND
RUN
COM-
MAND
Log Out 3 tb1-16 Terminal 16 Selection - - MTR
OVER-
LOAD
SPEED
REG RLS
Log Out 4 tb1-17 Terminal 17 Selection - - ENCODER
FAULT
RAMP
DOWN EN
Relay Coil 1 Relay 1 Function Selection - - FAULT READY
TO RUN
Relay Coil 2 Relay 2 Function Selection - - SPEED
REG RLS
SPEED
REG RLS
Table 2.5 Magnetek AC Drive Table
# Display Parameter Description Unit Range Defaults Factory