Night Service
268 Features Aspila EX Software Manual
Conditions
(A.) The NTCPU PCB has connections for a Night Mode switch. During installation, you connect
a mechanical switch to these contacts to provide an additional method of Night Mode switch-
ing. Refer to the system hardware manual for additional details.
(B.) The following programs are affected by Night Mode:
(C.) Almost all features are affected by Night Mode except for the following:
Dial Tone Detection
External Alarm Sensors
Flexible System Numbering
•Labelmaker
Pulse to Tone conversion
•SMDR
Volume Control
Default Setting
System is always in the Day Mode.
Programming
•10-05-01 : General Purpose Relay Setup
Define which relay circuits (5-8) on the 2PGDAD adapter are used for General Purpose
Relays.
•10-21-01 : NTCPU Hardware Setup, External Source Control Switch Selection
Specify the function of the relay switch for the external tone source control (0=External MOH
source, 1=BGM source, 2=External Speaker, 3=General Purpose Relay).
•11-10-01 : Service Code Setup (for System Administrator) - Day / Night Mode Switching
Customize the service code (818) to be used for day/night mode switching.
•11-12-50 : Service Code Setup (for Service Access) - General Purpose Relay
Define the service code to be used for turning the general purpose relay on and off
(default=880).
•11-15-09 : Service Code Setup, Administrative (for Hotel) - Transfer to Trunk Ring Group
Code
Enter the service code a user should dial when transferring a call to the Night Answer ring
group (defined in Program 22-05). This also allows the transferred call to ring over the Exter-
nal Paging (Program 31-05) so that any employee can answer the call. If unanswered, the call
can overflow to the destination defined in Program 22-08.
•12-01-01 : Night Mode Function Setup - Manual Night Service Enable
Allow (1) or prevent (0) Department Group extension members from activating Night Ser-
vice.
15-06 22-05 25-04 34-02
15-09 22-07 25-05 34-03
15-11 22-08 25-08 34-04
20-06 22-12 25-09
21-02 22-13 25-10
21-04 23-03 25-11
21-12 25-02 25-12