Program 10 : System Configuration Setup
10-03 : PCB Setup
424 Programming Aspila EX Software Manual
For BRIU Unit
Note 1. The start port number of a BRI line is displayed. Two logic ports are automatically
assigned to a BRI line.
Note 2. Each timer value of Layer3 are set up for every type of Program 81-06 (Trunk mode)
and Program 82-06 (S-Bus).
ISDN Line Number 01-08
Item
No.
Item Input Data Default
01 ISDN Line Mode 0- Not set
1- Trunk mode
2- S-Bus
3- NW mode (Leased Line)
4- NW mode (Interconnected Line)
5- NW Mode (Interconnected Line, Fixed layer 1=NT)
6- S-Point (Leased Line)
1
02 Logical Port Number
(see Note 1)
0: Net set
1: For Trunk mode (1-200)
2: For S-Bus (1-256)
0
03 Connection Type 0- P-MP
1- P-P
0
04 Layer 3 Timer Type (see Note 2) 1-5 1
05 - Not Currently Used -
CLIP Information Announcement
0- disable
1- enable
1
06 Connection Bus Mode (S-point only) 0- Extended Passive Bus
1- Short Passive Bus
0
07 S-point DID digits 0-4 0
08 Dial sending Mode 0- Enblock sending
1- Overlap sending
1
09 Dial Information Element
(Only for Overlap Sending Mode)
0- Keypad Facility
1- Called Party Number
1
10 Master/Slave System (NW mode only) 0- Slave System
1- Master System
0
11 Networking System Number (NW
mode only)
0-50 0
12 - Not Currently Used - 0
13 - Not Currently Used - 0
14 Service Protocol for S-Point 0- Keypad Facility
1- Specified Protocol for Aspila EX System
0