Program 10 : System Configuration Setup
10-03 : PCB Setup
Aspila EX Software Manual Programming 425
For PRIU Unit
Item
No.
Item Input Data Default
01 ISDN Line Mode 0- Not set
1- Trunk mode
2- S-Bus mode
3- NW mode (Leased Line)
4- NW mode (Interconnected Line)
5- NW Mode (Interconnected Line, Fixed Layer 1=NT)
6- S-Point (Leased Line)
1
02 Logical Port Number
(see Note 1)
1: for Trunk mode 1-200
2: for S-Bus 1-256
0
03 CRC Multi-frame(CRC4)
(Only E1[30B+D] Mode)
0- off
1- on
0
04 Layer 3 Timer Type 1-5 1
05 - Not Currently Used -
CLIP Information Announcement
0- disable
1- enable
1
06 Length of a cable 0- 0 40m
1- 40 81m
2- 81 122m
3- 122 162m
4- 162 200m
0
07 S-point DID digits 0-4 0
08 Dial Sending Mode 0- Enblock Sending
1- Overlap Sending
1
09 Dial Information Element
(Only for Overlap Sending Mode)
0- Keypad Facility
1- Called Party Number
1
10 Master/Slave System (NW mode only) 0- Slave System
1- Master System
0
11 Networking System Number (NW
mode only)
0-50 0
12 short / long-haul 0- short-haul
1- long-haul
0

Table of Contents