Program 10 : System Configuration Setup
10-03 : PCB Setup
426 Programming Aspila EX Software Manual
Note 1. The start port number of a PRI line is displayed. Thirty logic ports are automatically
assigned to a PRI line.
Note 2. Each timer value of Layer3 are set up for every type of Program 81-06 (Trunk mode)
and Program 82-06 (S-Bus).
For VOIPU Unit
13 Loss-Of-Signal detection limit In short-haul mode
0- 0.91V
1- 0.74V
2- 0.59V
3- 0.42V
4- 0.32V
5- 0.21V
6- 0.16V
7- 0.10V
In long-haul mode
0- 1.70V
1- 0.84V
2- 0.84V
3- 0.45V
4- 0.45V
5- 0.20V
6- 0.10V
7- not defined
0
14 Service Protocol for S-Point 0- Keypad Facility
1- Specified Protocol for Aspila EX System
0
Physical Port Number 01-32
Item
No.
Item Input Data Default
01 Trunk Logical Port Number 0-200 0
Item
No.
Item Input Data Default