Program 10 : System Configuration Setup
10-03 : PCB Setup
Aspila EX Software Manual Programming 427
For T1 Unit (North America Only)
Conditions
When changing a defined terminal type, first set the type to ‘0’ and then plug the new device in to
have the system automatically define it or redefine the type manually.
Feature Cross Reference
None
Physical Port Number 01-32
Item
No.
Item Input Data Default
01 Logical Port Number 0-200 0
02 Frame Type Setup 01- D4 (12 Multi Frame)
02- ESF (24 Multi Frame)
01
03 Zero Code Suppression Setup
ZCS_B8ZS
01- B8ZS
02- AMI/ZCS
01
04 DTI<->CSU Distance Setup 01= 0 feet – 133 feet
02= 133 feet – 266 feet
03= 266 feet – 399feet
04= 399 feet – 533 feet
05= 533 feet – 655 feet
01
05 T1 Clock Source Master/Slave 01- Slave
02- Master
01