– 112 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
BASIC SERVICE FEATURES
08
: Initial Data
BASIC SERVICE FEATURE SETTING DATA
380 Interval of ringer until detecting a ringing frequency from the
main PBX or Centrex.
Ringing is sent from D
term
until detection of the ringing fre-
quency.
0
1
As per CM08>381
As per CM35 Y=33
381 Interval of ringer until detecting a ringing frequency from the
main PBX or Centrex.
Ringing is sent from D
term
until detection of the ringing fre-
quency.
NOTE: Effective only when the 2nd data of CM08>380: 0.
0
1
No Ringer
Ringing Tone (0.5 seconds) is sent
once
382 Lamp indication of D
term
until detecting the kind of incoming
call from main PBX or Centrex.
The lamp is lit until detection of the ringing frequency.
0
1
Red steady light
120 IPM flash (As per CM35 Y=32)
386 Destination setting of Call Forwarding-All Calls/Busy Line/
Don’t Answer (No Answer)-Outside or Split Call Forwarding-
All Calls/Busy Line/Don’t Answer (No Answer)-Outside by
entering only a trunk access code
0
1
Restricted
Allowed
388 Holding/held party control for Music on Hold tenant basis 0
1
Held party control (tenant)
Holding party control (tenant)
390 D
term
tone ringer selection
NOTE 1: Set “0” (Available) by CM08>262 to allow the ring
test tone to be heard when using the “Feature + 3”
operation.
NOTE 2: When the ring tone 600 + 700 (Hz) is specified in
CM15 Y=83, 84 and/or CM35 Y=34, the ring tone
selection key of D
term
is ineffective.
0
1
By pressing Feature key and dialing 3
[2nd data=0 is set when Resi-
dent System program is
loaded.] NOTE 1
As per CM15 Y=83, 84, 93, CM35
Y=34, 164 NOTE 2
391 Lamp indication on D
term
0
1
Special
Standard
Continued on next page
INITIAL
INITIAL
CM08