– 135 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
BASIC SERVICE FEATURES
08
: Initial Data
BASIC SERVICE FEATURE SETTING DATA
825 Number of digits for a sequence used to communicate with the
PMS
[Series 3400]
0
1
3 digits (000-199)
2 digits (00-99)
826 Timing that the system sends a recovery process request to the
PMS
[Series 3400]
0
1
At every connection establishment
At the first connection establishment
only since system initialization
827 Parity check for MP Built-in SMDR on IP
[Series 3400]
0
1
None parity
Parity as for CM08>828
828 Kind of parity for MP Built-in SMDR on IP
[Series 3400]
0
1
Odd parity
Even parity
830 Kind of Center Office for Centralized Billing-CCIS
[Series 3400]
0
1
2000 IPS
2400 IPX
NOTE: This command is available in following conditions.
- Output Message Format of SMDR: NEAX 2400 IMS Extended Format
- Local Office: 2000 IPS
835 Printing of each hotel feature record with the printer that is
connected to the PMS using the PN-AP00-B/PN-AP00-D card
(with MRCA program)
[Series 3600]
0
1
Available
Not available
836 System clock used for the SMDR output of outgoing/incoming
call
[Series 3600]
0
1
System clock of site that the seized
trunk is accommodated (for outgoing
call)/System clock of site that the ter-
minated trunk is accommodated (for
outgoing call)
System clock of Main Site
837 System clock used for the SMDR output of station-to-station
call
[Series 3600]
0
1
System clock of the site that the
seized trunk/calling station is accom-
modated
System clock of Main Site
839 Sending of OAI SMFN with intermediate information via OAI
queue
[Series 3600]
0
1
To send
Not sent
Continued on next page