– 143 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
LAN INTERFACE ASSIGNMENT
0A
IPT INITIAL
IP-PAD INITIAL
SIP INITIAL
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
21 Echo Canceller for IP-PAD 00
31
LAN Interface
number
0
1
Echo Canceller OFF
Echo Canceller ON
NOTE 1: This command is available when PN-32IPLA/PN-32IPLA-A is used. For this feature, Series 3200 R6.2
software or before is required.
NOTE 2: Assign the Echo Canceller control by CM67 Y=03 in the conditions as follows.
• Series 3200 R6.2 software or later is used.
• PN-8IPLA is used.
22 NLP control for IP-PAD
[Series 3200 R6.2
(R6.2)]
00
31
LAN Interface
number
0
1
Available
Not available
NOTE 1: This command is available when PN-32IPLA/PN-32IPLA-A is used. For this feature, Series 3200 R6.2
software or before is required. When Series 3200 R6.2 or later is used, the Non Linear Processor Con-
trol is always provided.
NOTE 2: Set the second data to “0” usually.
23 Sending PAD level for SIP/
IP-PAD
00
31
LAN Interface
number
00
16
NONE
0 dB PAD
–16 dB PAD
0 dB PAD
NOTE 1: Set the PAD level by CM67 Y=02, when using Series 3200 R6.2 (R6.2) software or later.
NOTE 2: Set the second data in range of 0 to 14 dB (14 dB Loss), when using the PN-8IPLA/PN-8IPTA card.
This data is available only when the second data is set to 6 fixed by CM35 Y=19 when using the PN-
8IPTA card.
24 Receiving PAD level for
SIP/IP-PAD
00
31
LAN Interface
number
00
16
NONE
0 dB PAD
–16 dB PAD
0 dB PAD
NOTE 1: Set the PAD level by CM67 Y=02, when using Series 3200 R6.2 (R6.2) software or later.
NOTE 2: Set the second data in range of 0 to 14 dB (14 dB Loss), when using the PN-8IPLA/PN-8IPTA card.
This data is available only when the second data is set to 6 fixed by CM35 Y=19 when using the PN-
8IPTA card.
Continued on next page
~ ~ ~
~
~
~
~
~
JULY/01/2006
CM0A