– 174 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
LAN DATA ASSIGNMENT
0B
INITIAL
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
10 Port number of Device
Handler Manager (DHM)
Self port
[Series 3200 R6.2
(R6.2)]
70 Port number of
DHM Self port
which is used
for the commu-
nication
between main
site and remote
site
01024
65534
NONE
DHM Self port number 1024
DHM Self port number 65534
DHM Self port number 3300
NOTE 1: 128 ports from Base Port number you set are assigned as DHM Self
ports. 4 ports are used for the communication with one remote site.
The DHM Self port number that is used for the communication with each
remote site can be calculated as follows.
The value of second data + 4 × (site number-1)
NOTE 2: Since the DHM Self port number 0-1023 is reserved for specific applica-
tions (Well-Known port), the DHM Self port number 0-1023 cannot be
used.