– 192 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
UPDATING OF D
term
IP FIRMWARE/MP PROGRAM DOWNLOAD
(FTP)
0C
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
52 Downloading MP
program for MP Pro-
gram Download
(FTP) (Main Site/
Remote Site)
[Series 3700
R12.2]
XX01 Changeover
(changeback)
time
XX: 00: Main Site
No.
01-30:
Remote Site
No.
YYYY MM
DD HH mm
000000000000
CCC
NONE
YYYY: Year (2000-2099)
MM : Month (01-12)
DD : Date (01-31)
HH : Hour (00-23)
mm : Minutes (00-59)
Now executing
Clear
No data
NOTE 1: For MP program changeover, the system is reset automatically. Be sure not to
set the time while the system is operating.
NOTE 2: If a specified changeover time is passed while MP program is being downloaded,
the changeover of MP program is executed immediately (second data becomes
000000000000).
NOTE 3: If you set the second data to 000000000000 while MP program is being down-
loaded, the MP program changeover is executed after MP program download is
completed.
NOTE 4: If you set the second data to 000000000000 while matching the program version
of Flash ROMs, the MP program changeover is executed after the program ver-
sion matching is completed.
NOTE 5: This data is cleared after MP program changeover is completed.
NOTE 6: If the system is reset five times during about three minutes, the MP program
changeback is executed automatically.
NOTE 7: When the communication between Main Site and Remote Site cannot operate
normally, “HARDWARE ERROR” is displayed.
Continued on next page