EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - Page 217

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 193 – NWA-008844-001 Rev.5.0
91ch3001.fm
COMMAND CODE
TITLE:
UPDATING OF D
term
IP FIRMWARE/MP PROGRAM DOWNLOAD
(FTP)
0C
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
52 Downloading MP
program for MP Pro-
gram Download
(FTP) (Main Site/
Remote Site)
[Series 3700
R12.2]
XX03 MP program copy
from Flash ROM
1 (upgraded side)
to Flash ROM 0
(outdated side)
XX: 00: Main Site
No.
01-30:
Remote Site
No.
0
1
To copy
Not copied
NOTE 1: You can clear the previous MP program by this data setting.
NOTE 2: While the MP program is being downloaded, the second data 0 cannot be as-
signed. If you do that, “WAIT, BUSY NOW” is displayed.
NOTE 3: When the communication between Main Site and Remote Site cannot operate
normally, “HARDWARE ERROR” is displayed.
XX04 Status of MP pro-
gram download
(HEX)
XX: 00: Main Site
No.
01-30:
Remote Site
No.
XX YY ZZ XX: File type
00: MP program file
YY: Downloading file No.
ZZ : Total number of files
NOTE 1: If you set this data other than while the MP program download is executed,
“NONE” is displayed.
Display example:
If you are downloading the third file of 11 MP program files, “00030B” is dis-
played as the second data.
(File type 00=MP program file).
NOTE 2: When the communication between Main Site and Remote Site cannot operate
normally, “HARDWARE ERROR” is displayed.
Continued on next page
JULY/01/2006
CM0C

Table of Contents