– 221 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-1
12
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
33 Sending BLF message via
CCIS to Destination No.3
0
1
To send
Not sent
CM50 Y=08>3
34 Sending BLF message via
CCIS to Destination No.4
0
1
To send
Not sent
CM50 Y=08>4
35 Sending BLF message via
CCIS to Destination No.5
0
1
To send
Not sent
CM50 Y=08>5
36 Sending BLF message via
CCIS to Destination No.6
0
1
To send
Not sent
CM50 Y=08>6
37 Sending BLF message via
CCIS to Destination No.7
0
1
To send
Not sent
CM50 Y=08>7
38 Number of Memory Block
for CID Call Back
XXXXZZ
NONE
XXXX: Start Block Number (0000-4086)
ZZ : Number of Memory Block for CID Call
Back
01: 8 blocks
02: 16 blocks
03: 24 blocks
4 blocks
CM35 Y=150
NOTE 1: The memory block cannot be used in common by multiple stations.
Set the memory block to each D
term
station respectively.
NOTE 2: This command is not effective for a Single Line station/Virtual Line station/PS.
NOTE 3: The start block number set by the second data is as follows.
0000-1016 [Series 3800 software or before]
0000-4086 [Series 3900 software or later]
39 Location number of
D
term
IP for Local Connec-
tion
[Series 3100]
00
63
NONE
Location number 00
Location number 63
Location number 00
CM67
43 Group number for Group
Call by Pilot Number Dial-
ing
NOTE: Effective only
when CM13 Y=45
is 0.
00
19
NONE
Group Call No. 00
Group Call No. 19
Not assigned
CM13 Y=45
CM57 Y=10-
29